Representative sample
Ensuring a representative sample through closed, cooled sampling technology
Hot fluids such as thermal oil, hot water, boiler water or feed water must be sampled and analyzed regularly. It is most important to get a representative and accurate sample for the analysis. Thus the sample must be taken from a characteristic point of the hot flow.
An open hot sample, however, changes its composition when cooling down in an open container. Volatile components of the sample which boil below the sample temperature evaporate from open sample containers.
In the closed NESS Sample cooler, the sample is cooled with water and ensures a representative and exact sample.
The sampling connection can be installed either before system start-up or on a pressure gauge valve using a T-connector.
After installation to the system, the cooling water with a temperature of 5 to 30 °C is connected to the cooling water inlet valve. The used cooling water exits via the open drain pipe.
The Sample cooler has a wide range of applications: Max. sample temperature 400 °C / inlet pressure 40 bar
Functionality Sample cooler:
Thermal oil
cooling water